Professional manufacturer in the design and production of glass-lined equipment for over 20 years!
+86-533-2775537 / 2777386
15953332144
  1. Home > Products > Glass lined equipme > Glass lined reactor
Oil Heating Glass Lined Reactor
  • Oil Heating Glass Lined Reactor

Oil Heating Glass Lined Reactor


                                                                  Oil Heating Glass Lined Reactor

        Our company's oil heating glass lined reactor is produced by making high content silica into high-quality corrosion-resistant enamel glaze, and spray the glaze on the surface of the metal matrix. The glaze will be closely adherent to the surface of the metal after a high-temperature firing of 950℃. Therefore, possessing the dual nature that combines the corrosion resistance of glass and the strength of metal, it is good corrosion resistant equipment. Now, it has been widely applied in industries and departments, such as petroleum, chemicals, light industries, medicines, agriculture, pharmaceuticals, foods, fuels, and scientific research. 

        Corrosion resistance of oil heating glass lined reactor: it is resistant to the corrosions of inorganic acids, organic acids, organic solvents and weak alkalis in all concentrations (except for hydrofluoric acids, media that contain fluoride ion, and concentrated phosphoric acids and strong alkalis with a concentration ≥30% and a temperature ≥180℃).                           

MetInfo enterprise content manager system | MetInfo CMS          MetInfo enterprise content manager system | MetInfo CMS

Open type Glass Lined Reactor(K Series)                        Closed Type Glass Lined Reactor (F Series)

       Standard :HG/T2371-1992                                          Standard:HG/T2372-1992

                  MetInfo enterprise content manager system | MetInfo CMS               MetInfo enterprise content manager system | MetInfo CMS                MetInfo enterprise content manager system | MetInfo CMS

                             K50-100L                                  K200-500L                                 K1000-5000L

                         Nozzle Orientation                       Nozzle Orientation                       Nozzle Orientation

                                              MetInfo enterprise content manager system | MetInfo CMS          MetInfo enterprise content manager system | MetInfo CMS

                                                       F3000-5000L                              F10000-30000L

                                                    Nozzle Orientation                           Nozzle Orientation

 

                                                    Overall Dimensions and parameters of Oil Heating Glass Lined Reactor

Nominal
volume
 L

Actual
volume
L

Heat exchange area of Jacket
m2

Model of Reducer

Spec.of stuffing box. DN

Spec of discharge valve
DN

Stirred speed 
Rpm

Anchor and frame

Impeller
/paddle
K50710.34BLD0.8-1407085130
K1001280.66BLD0.8-1407085130
K2002471.26BLD1.1-1508085130
K3003691.75BLD3.0-3658085130
K5005882.64BLD3.0-3658085130
K100012504.54BLD4.0-38010085130
K150017205.34BLD4.0-38010085130
K200021607.02BLD4.0-38010085130
K300033808.61BLD5.5-39512585130
K5000517014BLD5.5-39512585130
K5000522013.4BLD5.5-39512585130
F300031008.61BLD5.5-395125/130
F5000505013.2BLD5.5-395125/130
F5000505013.2BLD5.5-395125/130
F100001167021.35BLD15-5110150/125
F150001645027.7BLD18.5-6160150/125
F200002179034.04BLD18.5-6160150/125
F300003261044.7BLD30-7160150/125
 
Nominal
volume
 L
Sizes(mm)Approx
Weight kg

D

D0

D1

D2

D3

D4

H

H1

H2

H3

L

h

Anchor and frameImpeller
/paddle
K50500350600706270/46530026594520305090477
K100600420700816270/565300300945217060110548
K200700490800918300/770350345954244060130728
K3008005609001048350/87035038011542770801501020
K50090063010001128350/107040040511543040801601225
K1000120084013001488400/1270500480127634301002101906
K1500130091014501622400/1470500505127636701002102383
K2000130091014501622400/1815500505127640101002102595
K30001600112017501964450/1810600580132641851302403891
K50001600112017502050450/2775600580132651501302404200
K50001750120019002150450/2480700620132650301302705274
F30001600112017501964600/2290120015013264300/2403554
F50001600112017502050600/3290120015013265300/2404388
F50001750120019002150600/2935120015013265000/2705161
F100002200154024002734800/3668142023021806170/3608150
F150002400168026002940800/4326140023021807280/36011970
F20000260018202800/90020004776/25021807710/40015000
F30000300021003200/110021005575/28022008360/45020700
 

                                                              Nozzle Sizes Table of Oil Heating Glass Lined Reactor

 

Nominal
volume L
abcdefghkmDischargeInlet/OutletVent
K50 10080Hand/
 sight
7070
70/
Light Hole 

70


703-201/2"
K200125/
Hand Hole
80708070/
Light Hole 
70
70/
Sight Glass 


803-251/2"
K300125/
Hand Hole
100708070/
Light Hole 
70
70/
Sight Glass 


803-251/2"
K500150/
Hand Hole
1007010080/
Light Hole 
125
80/
Sight Glass 


803-321/2"
K1000300×400125100100100/
Light Hole 
125100100/
Sight Glass 


1003-321/2"
K1500 2000300×400125100100125/
Light Hole 
125100125

1002-50 3-401/2"
K3000 K5000( φ1600)300×400125100100125/
Light Hole 
125100125

1252-70 3-501/2"
K5000 φ1750300×400125125150125/
Light Hole 
125125150

1254-701/2"
F3000 F5000(φ1600)300×400125100100125125100125

1255-701/2"
F5000 φ1750300×400125125125125150125150

1256-701/2"
F10000300×4002001501501501501251501501251504-80 3-703/4"
F150004502501501501501501251501501251507-1003/4"
F200004502501501501501501251501501251507-1003/4"
F300004502501501501501501251501501251507-1253/4"
 

                                                             Main Technical Performance of glass lined Reactor

 

K,F Series Glass Lined Reactor

 

Max.Operation pressure (Mpa)

Opertion temperature °C

Thickness of Glass lining
mm

 

High voltage test to glass lining layer
kv

Inside of vessel

 

Inside of jacket

 

Inside of vessel

 

Inside of jacket 

 

Stuffing box

 

Single face mechanical seal

 

Double-face mechanical seal

 

0.6

0~200

0~200

0.8~2.0

20 (Retest of User:6)

0.25

0.4

0.6~1.0

Remark

1. If the pressure exceeds 0.4Mpa or operation temperature is less than 0 oC you should tell us on the order

2. temperature difference Operation Limit for glass lining: cooling shock:110oC,thermo shock:120oC.(This is Destructive Test)