Vertical Glass Lined Storage Tank
Our company's vertical glass lined storage tank is produced by making high content silica into high-quality corrosion-resistant enamel glaze, and spray the glaze on the surface of the metal matrix. The glaze will be closely adherent to the surface of the metal after a high-temperature firing of 950℃. Therefore, possessing the dual nature that combines the corrosion resistance of glass and the strength of metal, it is good corrosion resistant equipment. Now, it has been widely applied in industries and departments, such as petroleum, chemicals, light industries, medicines, agriculture, pharmaceuticals, foods, fuels, and scientific research.
Corrosion resistance of vertical glass lined storage tank: it is resistant to the corrosions of inorganic acids, organic acids, organic solvents and weak alkalis in all concentrations (except for hydrofluoric acids, media that contain fluoride ion, and concentrated phosphoric acids and strong alkalis with a concentration ≥30% and a temperature ≥180℃).
Open type storage tank (K series storage tank) Closed type storage tank(F series storage tank)
Standard: HG/T2373-1992 Standard: HG/T2374-1992
Nozzle Orientation Nozzle Orientation
K200-500L K1000-2000L
Nozzle Orientation
F3000-5000L
Overall Dimensions and Nozzle Sizes of Vertical Glass Lined Storage Tank
Nominal volume L | Actual volume L | Sizes (mm) | Length of level gauge mm | Nozzle sizes | Nozzle length of lever gauge | Approx Kg | ||||||||||
D 1 | D 2 | D 3 | H 1 | H 2 | H | a | b | c | d | g | h | |||||
K200 | 258 | 600 | 360 | 420 | 300 | 965 | 1420 | 460 | 125 | 70 | 70 | 70 | 70 | 2-70 | 236 | |
K300 | 389 | 700 | 420 | 490 | 345 | 1070 | 1560 | 525 | 125 | 80 | 70 | 70 | 80 | 2-70 | 408 | |
K500 | 686 | 800 | 480 | 560 | 380 | 1370 | 2000 | 800 | 150 | 80 | 80 | 70 | 80 | 2-70 | 544 | |
K1000 | 1250 | 1000 | 600 | 700 | 430 | 1770 | 2350 | 1000 | 150 | 80 | 80 | 80 | 80 | 2-70 | 915 | |
K2000 | 2377 | 1300 | 780 | 910 | 505 | 1970 | 2610 | 1200 | 300x400 | 100 | 80 | 80 | 100 | 80 | 2-70 | 1400 |
F3000 | 3740 | 1600 | 600 | 1120 | 300 | 2295 | 2737 | 1000 | 125 | 70 | 70 | 70 | 125 | 2-70 | 1820 | |
F5000 | 5981 | 1600 | 600 | 1120 | 300 | 3265 | 3707 | 2-1200 | 125 | 70 | 70 | 70 | 125 | 4-70 | 2452 | |
F10000 | 11142 | 2200 | 700 | 1740 | 345 | 3337 | 4097 | 2-2000 | 125 | 80 | 70 | 70 | 125 | 4-70 | 4220 | |
F20000 | 22217 | 2600 | 700 | 345 | 4800 | 5485 | 3-1800 | 125 | 80 | 70 | 70 | 125 | 6-70 | 7400 | ||
F30000 | 33301 | 3000 | 700 | 345 | 5415 | 6205 | 3-2000 | 125 | 80 | 70 | 70 | 125 | 6-70 | 9700 | ||
F40000 | 41709 | 3000 | 700 | 345 | 6585 | 7375 | 4-1900 | 125 | 80 | 70 | 70 | 125 | 8-70 | 11260 | ||
F50000 | 51605 | 3000 | 700 | 345 | 7985 | 8775 | 4-1900 1-1700 | 125 | 80 | 70 | 70 | 125 | 10-70 | 13200 |
Main Technical Performance of Vertical Glass Lined Storage Tank
K,F Series Glass Lined Storage Tank | Max. Operation Pressure (Mpa) | Operation Temperature (oC) | Glass Lining Thickness (mm) | High Voltage Test to Glass lining Layer (kv) |
Inner of Vessel | ||||
0.25 | 0~150 | 0.8~2.0 | 20 (Retest of User: 6) | |
Remarks: temperature difference Operation Limit for glass lining: cooling shock: 110oC,thermo shock:120oC. (This is Destructive Test). |